PlumbingIntermediateCompressed Air

Compressed-Air Receiver Duration Calculator

Estimate ideal receiver support time between two gauge pressures at a constant net standard demand.

Why it matters: A transparent formula keeps the user-entered hydraulic, gas, or storage basis available for technical review.

User inputs

Enter field measurements

6 inputs
Select I-P or SI units for the entire input set.
ft³ or m³Internal receiver volume.
psig or kPagUpper receiver pressure.
psig or kPagLower receiver pressure.
psi or kPaLocal atmospheric pressure.
scfm or m³/minDemand minus simultaneous compressor delivery.

Calculated result

Engineering evaluation

Calculation complete—verify project criteria
Ideal receiver support time (t_r)163.265 min
Usable standard-air volume (V_s)
136.054 ft³

Engineering interpretation

The ideal receiver pressure range supports the net standard demand for 163.2653 minutes.

Important limitations

  • Ideal isothermal receiver screen only. Compressor response, heat transfer, control bands, pressure losses, receiver rating, safety relief, moisture, and demand variation are omitted.

Engineering knowledge center

Understand the calculation—not just the answer

2026-08-07 · Free Library
Governing relationships
V_s=V(P_1−P_2)/P_atm
t_r=60V_s/Q_n
Current substitution

V_s=100×(100−80)/14.7=136.0544; t_r=163.2653 min.

Calculation sequence

Step-by-step method

  1. Confirm the calculation boundary, units, and source of every input.
  2. Apply the displayed equation to the entered values.
  3. Review the result against governing criteria and documented uncertainty.

Equation legend

Inputs and calculated quantities

V
Receiver volume — ft³ or m³
P_1
Initial gauge pressure — psig or kPag
P_2
Final gauge pressure — psig or kPag
P_atm
Atmospheric pressure — psi or kPa
Q_n
Net standard-air demand — scfm or m³/min
t_r
Ideal receiver support time — min
V_s
Usable standard-air volume — ft³

Engineering calculation disclaimer

These engineering tools are provided for educational, preliminary evaluation, field verification, and commissioning support. Results depend on the accuracy of user-entered information and the assumptions stated for each calculation. Every colored status and comparison is a screening indicator only; project criteria, contract requirements, applicable codes, manufacturer instructions, measurement uncertainty, and authorized engineering judgment govern. The tools do not replace project-specific engineering analysis or the judgment of a licensed professional engineer.

Read the full use and limitation statement