Water-Heater Storage and Recovery Balance Calculator

Convert a peak mixed-water draw to stored-hot-water demand and subtract recovery available during the peak interval.

Why it matters: Peak draw, mixing fraction, recovery basis, and usable storage must be visible in one workflow.

User inputs

Enter field measurements

7 inputs
Select I-P or SI display units. Convert the entire input set before calculating.
gal or LMixed-water volume during the evaluated peak.
hDuration of the peak interval.
°F or °CDelivery temperature for the peak demand.
°F or °CCold-water temperature.
°F or °CStored hot-water temperature.
gal/h or L/hRecovery on the same storage-temperature basis.

Calculated result

Engineering evaluation

Calculation complete—verify project criteria
Preliminary net storage (Vˢ)90 gal
Hot-water fraction (xʰ)
75 %
Equivalent stored-hot demand (Vʰ)
150 gal
Recovered hot volume (Vʳ)
60 gal

Engineering interpretation

The entered peak requires 150 gal stored-hot equivalent, receives 60 gal recovery, and leaves 90 gal preliminary net storage.

Important limitations

  • Preliminary screen only. No equipment selection or acceptance is implied. Confirm demand profile, usable storage, recovery rating basis, stratification, dead volume, heat loss, mixing-valve capacity, scald/health policy, redundancy, code, and manufacturer data.

Engineering knowledge center

Understand the calculation—not just the answer

2026-08-07 · Free Library
Governing relationships
xʰ=(Tᵐ−Tᶜ)/(Tʰ−Tᶜ)
Vʰ=xʰ·Vᵐ
Vʳ=Rʰ·tᵖ
Vˢ=max(0,Vʰ−Vʳ)
Current substitution

xʰ=(120−60)/(140−60)=0.75; Vʰ=150; Vʳ=60×1=60; Vˢ=90.

Calculation sequence

Step-by-step method

  1. Calculate hot fraction from entered temperatures.
  2. Convert peak mixed demand to stored-hot demand.
  3. Subtract recovery during the peak and clip negative preliminary storage to zero.

Equation legend

Inputs and calculated quantities

Vᵐ
Peak mixed-water demand — gal or L
tᵖ
Peak interval — h
Tᵐ
Mixed delivery temperature — °F or °C
Tᶜ
Cold-water temperature — °F or °C
Tʰ
Stored hot-water temperature — °F or °C
Rʰ
Recovery at storage temperature — gal/h or L/h
Vˢ
Preliminary net storage — gal
xʰ
Hot-water fraction — %
Vʰ
Equivalent stored-hot demand — gal
Vʳ
Recovered hot volume — gal

Engineering calculation disclaimer

These engineering tools are provided for educational, preliminary evaluation, field verification, and commissioning support. Results depend on the accuracy of user-entered information and the assumptions stated for each calculation. Every colored status and comparison is a screening indicator only; project criteria, contract requirements, applicable codes, manufacturer instructions, measurement uncertainty, and authorized engineering judgment govern. The tools do not replace project-specific engineering analysis or the judgment of a licensed professional engineer.