CommissioningIntermediateTAB

TAB Flow Reconciliation Calculator

Reconcile entered airflow streams and calculate the imbalance between inflow and outflow totals.

Why it matters: Flow reconciliation can expose missing branches, inconsistent test bases, leakage, and measurement uncertainty.

User inputs

Enter field measurements

6 inputs
Select the unit convention used for the engineering quantities shown on this page.
cfm or m³/sTotal supply airflow entering the defined boundary.
cfm or m³/sAdditional makeup airflow not already included in supply.
cfm or m³/sReturn airflow leaving the defined boundary.
cfm or m³/sExhaust and relief airflow leaving the boundary.
%Project-specific imbalance review tolerance.

Calculated result

Engineering evaluation

Within entered screening criteria
Absolute airflow reconciliation imbalance (Bp)1.005 %
Total airflow into boundary (Qin)
10,000 cfm
Total airflow out of boundary (Qout)
9,900 cfm
Signed airflow imbalance (B)
100 cfm

Engineering interpretation

The defined boundary has 10000 cfm in and 9900 cfm out, for a signed imbalance of 100 cfm and absolute reconciliation difference of 1.005%.

Engineering knowledge center

Understand the calculation—not just the answer

2026-08-07 · Free Library
Governing relationships
Qin = Qs+Qo
Qout = Qr+Qe
B = Qin−Qout
Bp = |B|/((Qin+Qout)/2)×100
within entered criterion when Bp ≤ T
Current substitution

Qin = 10000+0 = 10000 cfm; Qout = 8500+1400 = 9900 cfm; Bp = 1.005%.

Calculation sequence

Step-by-step method

  1. Define a boundary and identify every inflow and outflow once.
  2. Sum inflows and outflows separately.
  3. Calculate signed and percent imbalance and compare with the entered tolerance.

Equation legend

Inputs and calculated quantities

Qs
Supply airflow into boundary — cfm or m³/s
Qo
Additional outdoor/makeup airflow — cfm or m³/s
Qr
Return airflow leaving boundary — cfm or m³/s
Qe
Exhaust/relief airflow leaving boundary — cfm or m³/s
T
Entered reconciliation tolerance — %
Bp
Absolute airflow reconciliation imbalance — %
Qin
Total airflow into boundary — cfm
Qout
Total airflow out of boundary — cfm
B
Signed airflow imbalance — cfm

Engineering calculation disclaimer

These engineering tools are provided for educational, preliminary evaluation, field verification, and commissioning support. Results depend on the accuracy of user-entered information and the assumptions stated for each calculation. Every colored status and comparison is a screening indicator only; project criteria, contract requirements, applicable codes, manufacturer instructions, measurement uncertainty, and authorized engineering judgment govern. The tools do not replace project-specific engineering analysis or the judgment of a licensed professional engineer.

Read the full use and limitation statement